Power Distribution Modules – Benching

Power Distribution Module - Circuit 1

Power Module, Circuit 1

  • Receives & distributes power for up to 5 workstations (5 station maximum, per power in-feed cable & 1 dedicated 20 Amp circuit)
  • ETL Listed, Conforms to UL 183 Power Distribution Systems Standards
  • Color coded quick connection ports to power in-feed & power distribution cables
  • 4 power outlets (120 VAC, 15 Amp) ā€“ 2 above, 2 below work surface
  • 2 USB charging ports (2.1 Amp for fast phone or tablet charging)
  • Scratch resistant, powder coated paint
  • Requires Workrite benching work surface/top
  • Benching Single Workcenter Power System Assembly Instructions
  • Benching Daisy Chain Power System Assembly Instructions

Power Distribution Module - Circuit 2

Power Module, Circuit 2

  • Receives & distributes power to 5 additional workstations (10 station maximum, per power in-feed cable & 2 dedicated 20 Amp circuits)
  • ETL Listed, Conforms to UL 183 Power Distribution Systems Standards
  • Color coded quick connection ports to power in-feed & power distribution cables
  • 4 power outlets (120 VAC, 15 Amp) ā€“ 2 above, 2 below work surface
  • 2 USB charging ports (2.1 Amp for fast phone or tablet charging)
  • Scratch resistant, powder coated pain
  • Requires Workrite benching work surface/top
  • Benching Single Workcenter Power System Assembly Instructions
  • Benching Daisy Chain Power System Assembly Instructions

Power Distribution Module - Jumper Block

Power Jumper Block

Power Distribution Cables – Benching

Power Distribution Cable - Below Desk Cross Cables

Below Desk Cross Cables

  • Connects Power Module to Power Jumper Block
  • Easy to use color coded quick connect plugs
  • Flexible metal conduit cable
  • Includes cable management clips
  • Available in 3 lengths (24″, 36″ & 48″) to match workstation sizes
  • Requires Workrite benching worksurface/top
  • Benching Daisy Chain Power System Assembly Instructions

Power Distribution Cable - Side to Side Jumper Cable

Side to Side Jumper Cable

Power Distribution Cable - Back to Back Jumper Cable

Back to Back Jumper Cable

Power In-feed Cables – Benching

Power In-Feed Cables - Hardwired with Quick Connect

Hardwired Power In-Feed Cable with Quick Connect

  • 4 wire, 2 circuit power in-feed cable
  • Hardwired connection, to be operated on one dedicated 20 Amp circuit for up to 5 stations or two dedicated 20 Amp circuits for up to 10 stations
  • A balanced electrical circuit configuration is recommended for 6 or more stations
  • Connection to the building wiring must be done by a qualified electrician according to national state & local codes
  • Color coded quick connect plug to Power Module for easy installation
  • 96″ flexible metal conduit cable with black mesh cover
  • Requires Workrite benching worksurface/top
  • Benching Daisy Chain Power System Assembly Instructions

Power In-Feed Cables - Hardwired with Dual Quick Connect

Hardwired Power Outlet with Dual Quick Connect Power In-feed Cable

  • Fits standard electrical j-box
  • Use DecoraĀ® face plate for trim (not provided )
  • 4 wire, 2 circuit power in-feed wiring Hard wired connection, to be operated on one dedicated 20 Amp circuit for up to 5 stations or two dedicated 20 Amp circuits for up to 10 stations
  • A balanced electrical circuit configuration is recommended for 6 or more stations
  • Connection to the building wiring must be done by a qualified electrician according to national state & local codes

Quick Connect Power In-Feed Cable:

  • Easy to use color coded quick connect plugs
  • 96″ flexible metal conduit cable with black mesh cover

Requires Workrite benching worksurface/top

Power In-Feed Cables - for Standard Wall Outlets

Power In-feed Cable for Standard Wall Outlets